Home » IMCL & IMSL Submersible Level Transmitters
IMCL & IMSL Submersible Level Transmitters
The IMCL and IMSL submersible level transmitters are designed for continuous hydrostatic level measurement in rivers, reservoirs, wells, boreholes and tanks. Both are IP submersible probes housed in 316L stainless steel as standard and are temperature compensated and calibrated, supplied with a traceable serial number and calibration certificate. Electronics use a microprocessor-based amplifier (no adjustment pots) for stable, repeatable performance.
The key difference is media suitability:
IMSL: for water, oil and other non‑aggressive chemicals, using piezo‑resistive media isolated silicon sensing with a stainless steel diaphragm.
IMCL: for water, fuels, oils and aggressive chemicals, using a ceramic piezo‑resistive sensor with excellent corrosion resistance and a thin stainless steel diaphragm; housing options extend to high grade Duplex stainless steel or PVC for harsher environments.
Wide range of use in submersible conditions
Easy installation
Selection of housing & cable materials to maximise media compatibility
Variety of outputs including mV, Volts and mA
Supplied calibrated with certification
IMCL & IMSL Available Options
- Model selection: IMSL (non‑aggressive media) or IMCL (aggressive media)
- Pressure / level range selection (see ranges below)
- Output options (2/3/4 wire options including 4–20mA / voltage options)
- Housing material options (IMCL includes 316L stainless steel, Duplex stainless steel or PVC)
- Cable / wetted material selections to suit media compatibility
IMCL & IMSL Submersible Level Transmitter Applications
IMSL typical applications (non‑aggressive liquids):
- River level
- Reservoir level
- Tank level
- Borehole level
- Aquifer level
- Environmental monitoring
- V‑notch weir flow measurement
IMCL typical applications (including aggressive liquids):
- Environmental engineering (sewage and water treatment plants)
- Depth / level measurement in wells and open waters
- Ground water level measurement
- Level measurement in open tanks, including aggressive media
IMCL & IMSL Pressure / Level Ranges
- IMSL ranges: 0.5 to 100 mWG
- IMCL ranges: 10 to 100 mWG
IMCL & IMSL Output Signal & Supply
- Outputs & comms: 2/3/4 wire 4–20mA / 0–5V DC (option dependent)
- Power supply: 9–36 V DC
- Operating temperature range: -20 to +60°C
- Diameter: 25 mm
- Approvals: CE compliant